RJH-880 series are a peroxide cross-linking silicone rubber for the insulation of fire-resistant safety cables. When exposed to a flame, it can transform itself into an insulating and ceramic material. It can withstand thermal stress and mechanical impact, maintain circuit integrity in case of fire.
Typical general characteristics
Property | Inspection method | Value |
Appearance | white | |
Density @23℃ | ISO 1183-1 A | 1.35g/cm3 |
After addition of 1.2% DCBP (50%) and cured for 10min at 120℃ and post cure for 4h at 200℃ | ||
Hardness Shore A | DIN 53505 | 67 |
Tensile strength | DIN 53504 S 1 | 7.8Mpa |
Elongation at break | DIN 53504 S 1 | 298% |
Tear Strength | ASTM D 624 B | 16KN/m |
After addition of 0.6% DBPMH (95%) and cured for 10min at 170℃ and post cure for 4h at 200℃ | ||
Hardness Shore A | DIN 53505 | 70 |
Tensile strength | DIN 53504 S 1 | 8.4Mpa |
Elongation at break | DIN 53504 S 1 | 364% |
Tear Strength | ASTM D 624 B | 21KN/m |
After addition of 0.6% DBPMH (95%) and cured for 10min at 170℃ and post cure for 4h at 200℃ and after aging 10 days @200℃ | ||
Hardness Shore A | DIN 53505 | 79 |
Tensile strength | DIN 53504 S 1 | 7.4Mpa |
Elongation at break | DIN 53504 S 1 | 192% |
Safety cables test,fulfill the requirement as below | ||
DIN4102 PART12 | UL94V0 | EN50200 |
IEC60331-11 |
Note: The test data is for reference only.